Difference between revisions of "1990 Wanderlodge Wide Body Pusher (WB)"
Jump to navigation
Jump to search
Line 75: | Line 75: | ||
Operating tips (need to build this out more formally): | Operating tips (need to build this out more formally): | ||
− | * Electrical issues check the following things before troubleshooting: | + | *Electrical issues check the following things before troubleshooting: |
− | *# A/T switch on dash | + | *#A/T switch on dash |
− | *# Master Electronics switch in driver side airline compartment | + | *#Master Electronics switch in driver side airline compartment |
− | *# Battery disconnect switch | + | *#Battery disconnect switch |
− | *# Breaker panel in bedroom behind mirrors | + | *#Breaker panel in bedroom behind mirrors |
+ | |||
+ | <br /> | ||
+ | |||
+ | == Issues experienced and resolutions: == | ||
+ | |||
+ | ===== Generator overheating and shutting down, radiator fan not running ===== | ||
+ | |||
+ | * Replaced capacitor in junction box on side of fan; common fan/capacitor used in household furnaces | ||
+ | |||
+ | <br /> | ||
+ | |||
+ | ==== City Water hook-up leaking water from fitting on outside of bus ==== | ||
+ | |||
+ | * Removed and replaced the water pressure regulator by removing the the protective cover under the wheel well, removing wall chase cover and re-installing new regulator | ||
+ | ** Note: newer water pressure regulators have a 1/4" bigger cup and will not fit in existing location without cutting larger hole in floor, possible to just replace the regulator inside cup without replacing whole component. | ||
+ | |||
==Living Area Facilities== | ==Living Area Facilities== |
Revision as of 20:19, 15 August 2019
Overview
Operation
Operating tips (need to build this out more formally):
- Electrical issues check the following things before troubleshooting:
- A/T switch on dash
- Master Electronics switch in driver side airline compartment
- Battery disconnect switch
- Breaker panel in bedroom behind mirrors
Issues experienced and resolutions:
Generator overheating and shutting down, radiator fan not running
- Replaced capacitor in junction box on side of fan; common fan/capacitor used in household furnaces
City Water hook-up leaking water from fitting on outside of bus
- Removed and replaced the water pressure regulator by removing the the protective cover under the wheel well, removing wall chase cover and re-installing new regulator
- Note: newer water pressure regulators have a 1/4" bigger cup and will not fit in existing location without cutting larger hole in floor, possible to just replace the regulator inside cup without replacing whole component.
Living Area Facilities
Automated drapery controls in main living area and in rear bedroom, re-stringing instructions are located here.
Electrical Systems
Water Distribution and Drainage
Liquefied Petroleum Gas (LPG) Systems
Air Brake Systems
Maintenance Data
Specifications and Data
Engine and Chassis Specifications
Changing Wheels & Tires
Battery Maintenance
Exterior Care
Equipment Manufactures Information
Diagrams