Difference between revisions of "Lightwood Drapery Controls"

From Wanderlodge Wiki
Jump to navigation Jump to search
 
(7 intermediate revisions by one other user not shown)
Line 1: Line 1:
 
Drapery controls made by Lightwood Manufacturing Inc.
 
Drapery controls made by Lightwood Manufacturing Inc.
 
Drapery Control Systems instructions include steps on how to re-string.
 
[[File:Lightwood Drapery Control Instructions.jpg|border|left|thumb]]
 
<br />
 
 
 
 
 
 
 
 
 
 
<br />
 
  
 
==Installation Instructions==
 
==Installation Instructions==
 +
[[File:Lighwood Drapery Controls Installation Figures.png|right|frameless|565x565px]]
  
 
===Mounting Plate===
 
===Mounting Plate===
 
1.  Place mounting plate as near floor as conveniently possible*, behind drapery and directly below the cord outlets in traverse rod. (Fig. 1 at right shows dotted outline of controller when in place.) A straight line (vertical) pull on drapery cord is necessary for correct performance of the controllers.
 
1.  Place mounting plate as near floor as conveniently possible*, behind drapery and directly below the cord outlets in traverse rod. (Fig. 1 at right shows dotted outline of controller when in place.) A straight line (vertical) pull on drapery cord is necessary for correct performance of the controllers.
  
== <nowiki>*</nowiki>(This will allow maximum choice of placement of the 10-foot remote switch extension cord.) ==
+
<nowiki>*</nowiki>(This will allow maximum choice of placement of the 10-foot remote switch extension cord.)
 
 
  
 
2. After securing mounting plate with screws provided, snap controller onto plate by resting  lower edge  of case in cradle of the two hooks, press upper end of same against wall. Controller will noticeably snap into locked position firmly against wall and mounting plate.
 
2. After securing mounting plate with screws provided, snap controller onto plate by resting  lower edge  of case in cradle of the two hooks, press upper end of same against wall. Controller will noticeably snap into locked position firmly against wall and mounting plate.
<br />
+
[[File:Drapery Wheel Replacement.jpg|thumb]]
  
 
===Threading Controller===
 
===Threading Controller===
Line 31: Line 17:
 
'''Models OM, DM/R, 8-546-1:'''
 
'''Models OM, DM/R, 8-546-1:'''
  
After controller is mounted to wall remove snap-on cover to expose drive  mechanism.  (Fig.  2).  Line up drapery cords in manner illustrated in upper right and grab right hand cord firmly, pulling it through, between pressure roller B and drive roller A.  Take left hand cord and repeat procedure by pulling it through, between drive roller A and pressure roller C. Then pull up on right hand cord until cord loop is pulled tightly around bottom of drive roller A. (Remove slack as indicated below - see Slack Adjustment.) While holding cords in position shown in Fig. 2, replace cover. Threading is complete and controller may now be plugged into 110 to 120 VAC power outlet.
+
After controller is mounted to wall remove snap-on cover to expose drive  mechanism.  (Fig.  2).  Line up drapery cords in manner illustrated in upper right and grab right hand cord firmly, pulling it through, between pressure roller B and drive roller A.  Take left hand cord and repeat procedure by pulling it through, between drive roller A and pressure roller C. Then pull up on right hand cord until cord loop is pulled tightly around bottom of drive roller A. (Remove slack as indicated below - see Slack Adjustment.) While holding cords in position shown in (Fig. 2), replace cover. Threading is complete and controller may now be plugged into 110 to 120 VAC power outlet.  
 +
 
 +
Control switch on this model is a "momentary<nowiki>''</nowiki> switch. When  held down  on  the side next to remote cord, controller pulls down  on right cord; when held down on side away from cord, controller pulls down on left hand cord. When  released  from either  side, switch returns to "off<nowiki>''</nowiki> position and power is disconnected from motor.       
  
Control switch on this model is a "momentary<nowiki>''</nowiki> switch. When  held down  on  the side next to remote cord, controller pulls down  on right cord; when held down on side away from cord, controller pulls down on left hand cord. When  released  from either  side, switch returns   ' to "off<nowiki>''</nowiki> position and power is disconnected from motor.
+
'''Models A, AIR, DAIR, SCA, DA, 9938, 9939, 8-500-1, 8-508-1:'''      
'''Models A, AIR, DAIR, SCA, DA, 9938, 9939, 8-500-1, 8-508-1:'''
 
After  controller   is  mounted   to   wall remove snap-on cover to expose drive mechanism. (See Fig. 3.)  Line up drapery cords in manner illustrated in upper right and grasp right hand cord firmly, pulling it through, between pressure roller B and driver roller A, pulling tightly around bottom of A and then between A and pressure roller C. Place cords in slots in actuator slide D as shown, holding it in position  until cover is re­placed.  Threading is complete and controller may now be plugged into 110 to 120 VAC power outlet.
 
  
placed. Threading is complete and controller may now
+
After  controller   is  mounted   to   wall remove snap-on cover to expose drive mechanism. (See Fig. 3.)  Line up drapery cords in manner illustrated in upper right and grasp right hand cord firmly, pulling it through, between pressure roller B and driver roller A, pulling tightly around bottom of A and then between A and pressure roller C. Place cords in slots in actuator slide D as shown, holding it in position  until cover is re­placed.  Threading is complete and controller may now be plugged into 110 to 120 VAC power outlet.               
  
'''REVERSING  DIRECTION OF DRAPE TRAVEL ''' is ac­complished only '''after''' it has reached end of run (fully open or fully closed). At that time depressing switch on the opposite side will start drape travel in other direction.
+
'''REVERSING  DIRECTION OF DRAPE TRAVEL ''' is ac­complished only '''after''' it has reached end of run (fully open or fully closed). At that time depressing switch on the opposite side will start drape travel in other direction.  
  
 
==Directions for Use==
 
==Directions for Use==
'''MODELS  DA/RI, A/RD, 9940:'''
+
'''MODELS DA/RI, A/RD, 9940:'''
  
 
'''Position 1:''' Controller drive runs in counter-clockwise direction to end of run and automatically shuts off.
 
'''Position 1:''' Controller drive runs in counter-clockwise direction to end of run and automatically shuts off.
Line 52: Line 38:
 
<br />
 
<br />
  
== Slack Adjustment ==
+
==Slack Adjustment==
 
While slack is no problem in the correct  performance  of your controller, excessive slack is undesirable and should be removed by taking up at master carrier  at end of traverse rod.
 
While slack is no problem in the correct  performance  of your controller, excessive slack is undesirable and should be removed by taking up at master carrier  at end of traverse rod.
 
<br />
 
<br />
  
== Internal Thermoswitch Shut-Off ==
+
==Internal Thermoswitch Shut-Off==
 
Your controller is designed for normal use. If run exces­sively, such as every few minutes, the self-contain d thermoswitch will shut off the motor for several min­utes.  Functionally,  the  thermoswitch  prolongs the life of product and prevents inadvertent or accidental abuse of mechanism.  
 
Your controller is designed for normal use. If run exces­sively, such as every few minutes, the self-contain d thermoswitch will shut off the motor for several min­utes.  Functionally,  the  thermoswitch  prolongs the life of product and prevents inadvertent or accidental abuse of mechanism.  
  
== Load ==
+
==Load==
 
Models are rated at the following maximum pull on drapery cord and drapery weight. Units should not be allowed to pull more than the recommended weight.
 
Models are rated at the following maximum pull on drapery cord and drapery weight. Units should not be allowed to pull more than the recommended weight.
 
{| class="wikitable"
 
{| class="wikitable"
Line 85: Line 71:
 
|18
 
|18
 
|54
 
|54
|}
+
|}[[File:Lightwood Drapery Control Instructions.jpg|border|left|thumb]]

Latest revision as of 19:24, 19 April 2021

Drapery controls made by Lightwood Manufacturing Inc.

Installation Instructions

Lighwood Drapery Controls Installation Figures.png

Mounting Plate

1.  Place mounting plate as near floor as conveniently possible*, behind drapery and directly below the cord outlets in traverse rod. (Fig. 1 at right shows dotted outline of controller when in place.) A straight line (vertical) pull on drapery cord is necessary for correct performance of the controllers.

*(This will allow maximum choice of placement of the 10-foot remote switch extension cord.)

2. After securing mounting plate with screws provided, snap controller onto plate by resting  lower edge  of case in cradle of the two hooks, press upper end of same against wall. Controller will noticeably snap into locked position firmly against wall and mounting plate.

Drapery Wheel Replacement.jpg

Threading Controller

CAUTION: Do not plug controller into outlet until com­pletely threaded and cover returned to place.

Models OM, DM/R, 8-546-1:

After controller is mounted to wall remove snap-on cover to expose drive  mechanism.  (Fig.  2).  Line up drapery cords in manner illustrated in upper right and grab right hand cord firmly, pulling it through, between pressure roller B and drive roller A.  Take left hand cord and repeat procedure by pulling it through, between drive roller A and pressure roller C. Then pull up on right hand cord until cord loop is pulled tightly around bottom of drive roller A. (Remove slack as indicated below - see Slack Adjustment.) While holding cords in position shown in (Fig. 2), replace cover. Threading is complete and controller may now be plugged into 110 to 120 VAC power outlet.

Control switch on this model is a "momentary'' switch. When  held down  on  the side next to remote cord, controller pulls down  on right cord; when held down on side away from cord, controller pulls down on left hand cord. When  released  from either  side, switch returns to "off'' position and power is disconnected from motor.

Models A, AIR, DAIR, SCA, DA, 9938, 9939, 8-500-1, 8-508-1:

After  controller   is  mounted   to   wall remove snap-on cover to expose drive mechanism. (See Fig. 3.)  Line up drapery cords in manner illustrated in upper right and grasp right hand cord firmly, pulling it through, between pressure roller B and driver roller A, pulling tightly around bottom of A and then between A and pressure roller C. Place cords in slots in actuator slide D as shown, holding it in position  until cover is re­placed. Threading is complete and controller may now be plugged into 110 to 120 VAC power outlet.

REVERSING  DIRECTION OF DRAPE TRAVEL  is ac­complished only after it has reached end of run (fully open or fully closed). At that time depressing switch on the opposite side will start drape travel in other direction.

Directions for Use

MODELS DA/RI, A/RD, 9940:

Position 1: Controller drive runs in counter-clockwise direction to end of run and automatically shuts off.

Position 2: Activates momentary switch (Sw2)  and from momentary switch controller may be run in either direction  from  any  point .  installation and operation of (Sw2) should always be within visual range of drapery to permit person operating same to see when to stop drapery travel.

Position  3:  Controller  drive  runs  in clockwise  direction until end of run and automatically shuts off.


Slack Adjustment

While slack is no problem in the correct  performance  of your controller, excessive slack is undesirable and should be removed by taking up at master carrier  at end of traverse rod.

Internal Thermoswitch Shut-Off

Your controller is designed for normal use. If run exces­sively, such as every few minutes, the self-contain d thermoswitch will shut off the motor for several min­utes.  Functionally,  the  thermoswitch  prolongs the life of product and prevents inadvertent or accidental abuse of mechanism.

Load

Models are rated at the following maximum pull on drapery cord and drapery weight. Units should not be allowed to pull more than the recommended weight.

Model Maximum Pull (lbs.) Maximum Drapery Weight (lbs.)
8-546-1 14 40
DM,DMR 25 75
A,A/R, A/RD,9938,8-500-1 16 48
DA, DA/R, DA/RI, 8-508-1, 9938, 9940 22 66
SCA 18 54
Lightwood Drapery Control Instructions.jpg