- Electrical issues check the following things before troubleshooting:
- A/T switch on dash
- Master Electronics switch in driver side airline compartment
- Battery disconnect switch
- Breaker panel in bedroom behind mirrors
Issues experienced and resolutions:
Generator overheating and shutting down, radiator fan not running
- Replaced capacitor in junction box on side of fan; common fan/capacitor used in household furnaces
City Water hook-up leaking water from fitting on outside of bus
- Removed and replaced the water pressure regulator by removing the the protective cover under the wheel well, removing wall chase cover and re-installing new regulator
- Note: newer water pressure regulators have a 1/4" bigger cup and will not fit in existing location without cutting larger hole in floor, possible to just replace the regulator inside cup without replacing whole component.