Changes

Jump to navigation Jump to search
no edit summary
Line 15: Line 15:  
<br />
 
<br />
   −
== Installation Instructions ==
+
==Installation Instructions==
   −
=== Mounting Plate ===
+
===Mounting Plate===
 
1.  Place mounting plate as near floor as conveniently possible*, behind drapery and directly below the cord outlets in traverse rod. (Fig. 1 at right shows dotted outline of controller when in place.) A straight line (vertical) pull on drapery cord is necessary for correct performance of the controllers.
 
1.  Place mounting plate as near floor as conveniently possible*, behind drapery and directly below the cord outlets in traverse rod. (Fig. 1 at right shows dotted outline of controller when in place.) A straight line (vertical) pull on drapery cord is necessary for correct performance of the controllers.
   −
<nowiki>*</nowiki>(This will allow maximum choice of placement of the 10-foot remote switch extension cord.)
+
== <nowiki>*</nowiki>(This will allow maximum choice of placement of the 10-foot remote switch extension cord.) ==
      Line 26: Line 26:  
<br />
 
<br />
   −
=== Threading Controller ===
+
===Threading Controller===
 
CAUTION: Do not plug controller into outlet until com­pletely threaded and cover returned to place.
 
CAUTION: Do not plug controller into outlet until com­pletely threaded and cover returned to place.
   Line 41: Line 41:  
'''REVERSING  DIRECTION OF DRAPE TRAVEL ''' is ac­complished only '''after''' it has reached end of run (fully open or fully closed). At that time depressing switch on the opposite side will start drape travel in other direction.
 
'''REVERSING  DIRECTION OF DRAPE TRAVEL ''' is ac­complished only '''after''' it has reached end of run (fully open or fully closed). At that time depressing switch on the opposite side will start drape travel in other direction.
   −
== Directions for Use ==
+
==Directions for Use==
 
'''MODELS  DA/RI, A/RD, 9940:'''
 
'''MODELS  DA/RI, A/RD, 9940:'''
   Line 49: Line 49:     
'''Position  3:'''  Controller  drive  runs  in clockwise  direction until end of run and automatically shuts off.
 
'''Position  3:'''  Controller  drive  runs  in clockwise  direction until end of run and automatically shuts off.
 +
 +
<br />
 +
 +
== Slack Adjustment ==
 +
While slack is no problem in the correct  performance  of your controller, excessive slack is undesirable and should be removed by taking up at master carrier  at end of traverse rod.
 +
<br />
 +
 +
== Internal Thermoswitch Shut-Off ==
 +
Your controller is designed for normal use. If run exces­sively, such as every few minutes, the self-contain d thermoswitch will shut off the motor for several min­utes.  Functionally,  the  thermoswitch  prolongs the life of product and prevents inadvertent or accidental abuse of mechanism.
 +
 +
== Load ==
 +
Models are rated at the following maximum pull on drapery cord and drapery weight. Units should not be allowed to pull more than the recommended weight.
 +
{| class="wikitable"
 +
!Model
 +
!Maximum Pull (lbs.)
 +
!Maximum Drapery Weight (lbs.)
 +
|-
 +
|8-546-1
 +
|14
 +
|40
 +
|-
 +
|DM,DMR
 +
|25
 +
|75
 +
|-
 +
|A,A/R, A/RD,9938,8-500-1
 +
|16
 +
|48
 +
|-
 +
|DA, DA/R, DA/RI, 8-508-1, 9938, 9940
 +
|22
 +
|66
 +
|-
 +
|SCA
 +
|18
 +
|54
 +
|}

Navigation menu