Line 75: |
Line 75: |
| Operating tips (need to build this out more formally): | | Operating tips (need to build this out more formally): |
| | | |
− | *Electrical issues check the following things before troubleshooting:
| + | ==== Electrical issues check the following things before troubleshooting ==== |
− | *#A/T switch on dash
| |
− | *#Master Electronics switch in driver side airline compartment
| |
− | *#Battery disconnect switch
| |
− | *#Breaker panel in bedroom behind mirrors
| |
| | | |
− | <br /> | + | #A/T switch on dash |
| + | #Master Electronics switch in driver side airline compartment |
| + | #Battery disconnect switch |
| + | #Breaker panel in bedroom behind mirrors<br /> |
| | | |
− | == Issues experienced and resolutions: == | + | ==Issues experienced and resolutions:== |
| | | |
− | ===== Generator overheating and shutting down, radiator fan not running ===== | + | =====Generator overheating and shutting down, radiator fan not running===== |
| | | |
− | * Replaced capacitor in junction box on side of fan; common fan/capacitor used in household furnaces | + | *Replaced capacitor in junction box on side of fan; common fan/capacitor used in household furnaces |
| | | |
| <br /> | | <br /> |
| | | |
− | ==== City Water hook-up leaking water from fitting on outside of bus ==== | + | ==== Generator starts but blows fuse after few seconds and will not keep running ==== |
| + | |
| + | * Starter solenoid shorting, disassemble and clean/replace worn connectors OR hit starter with hammer a few times and try again (works!) |
| + | |
| + | <br /> |
| + | ====City Water hook-up leaking water from fitting on outside of bus==== |
| | | |
− | * Removed and replaced the water pressure regulator by removing the the protective cover under the wheel well, removing wall chase cover and re-installing new regulator | + | *Removed and replaced the water pressure regulator by removing the the protective cover under the wheel well, removing wall chase cover and re-installing new regulator |
− | ** Note: newer water pressure regulators have a 1/4" bigger cup and will not fit in existing location without cutting larger hole in floor, possible to just replace the regulator inside cup without replacing whole component. | + | **Note: newer water pressure regulators have a 1/4" bigger cup and will not fit in existing location without cutting larger hole in floor, possible to just replace the regulator inside cup without replacing whole component. |
| | | |
| | | |